SAMPLE REPORT | FICTIONAL PROPERTY | SYNTHETIC DATA

SAMPLE REPORT | ASHRAE Level 1 Energy Assessment

Bright Coin Laundry

SAMPLE ADDRESS: 44 Lantern Mill Road, White River Junction, VT 05001

Report ID
SAMPLE-BA-L1-0001
Assessment date
July 11, 2026
Business segment
Laundromat
Climate zone
6A
Gross floor area
5,200 sf [sample-property-profile]
Report status
SAMPLE REPORT - Draft assessment

Executive Summary

This draft assessment reviews a complete 12-month utility baseline and owner-provided walkthrough evidence. Site EUI is 304.2 kBtu/sf/yr and annual utility cost is $45,590 [sample-utility-ledger]. Compared with the cited benchmark, site EUI is 715.6% above the reference [benchmark-reference]. Recommended actions are separated into no-cost and low-cost measures and capital measures.

Utility Analysis and Benchmark Verdict

The building site EUI is 715.6% above the cited benchmark reference. [benchmark-reference]

Utility metricResultSource
Annual electricity184,600 kWh[sample-utility-ledger]
Annual natural gas9,520 therms[sample-utility-ledger]
Annual utility cost$45,590[sample-utility-ledger]
Site energy1,581,881.3 kBtu[sample-utility-ledger]
Site EUI304.2 kBtu/sf/yr[sample-utility-ledger]
Energy cost intensity$8.77/sf/yr[sample-utility-ledger]
Peak billed demand78.0 kW[sample-utility-ledger]
Benchmark metricActualReferenceDifferenceSource
Site EUI304.2 kBtu/sf/yr37.3 kBtu/sf/yr715.6% above[benchmark-reference]
Energy cost intensity8.8 USD/sf/yr1.1 USD/sf/yr735.0% above[benchmark-reference]

Synthetic 12-month bill ledger

All values in this table are fictional sample inputs, not customer records.

PeriodkWhThermsPeak kWCostSource
2025-0814,80054066.0$3,420[sample-utility-ledger]
2025-0914,50059064.0$3,350[sample-utility-ledger]
2025-1014,20072063.0$3,380[sample-utility-ledger]
2025-1113,90092062.0$3,650[sample-utility-ledger]
2025-1215,1001,18068.0$4,250[sample-utility-ledger]
2026-0116,4001,26074.0$4,680[sample-utility-ledger]
2026-0217,2001,13078.0$4,520[sample-utility-ledger]
2026-0316,80090076.0$4,080[sample-utility-ledger]
2026-0415,50069070.0$3,650[sample-utility-ledger]
2026-0514,90057067.0$3,420[sample-utility-ledger]
2026-0615,20052069.0$3,480[sample-utility-ledger]
2026-0716,10050073.0$3,710[sample-utility-ledger]

Walkthrough Findings by System

Lighting (generic screen)

  • Opportunity: The synthetic inventory records 32 fluorescent fixtures in the customer and folding areas, with no daylight or occupancy controls. [sample-walkthrough]

HVAC controls (generic screen)

  • Opportunity: The synthetic thermostat schedule holds occupied setpoints for all 168 hours each week although the sample business is open 112 hours. [sample-walkthrough]

Building envelope (generic screen)

  • Follow Up: A visible gap is recorded at the rear service door; measure leakage before assigning savings. [sample-walkthrough]

Plug and process loads (generic screen)

  • Observed: Laundry equipment dominates the sample process load; two vending machines and the change system remain energized continuously. [sample-walkthrough]

Laundry equipment (segment screen)

  • Opportunity: Eight of 20 synthetic washer nameplates are more than 12 years old and are candidates for end-of-life high-efficiency replacement. [sample-walkthrough]

Dryer airflow (segment screen)

  • Follow Up: The sample lint-path inspection records partial restriction at two dryer-bank terminations; clean and measure cycle performance before claiming savings. [sample-walkthrough]

Domestic hot water (segment screen)

  • Observed: The fictional gas water heater is recorded at 82% thermal efficiency; 18 feet of accessible hot-water piping is uninsulated. [sample-walkthrough]

Recommended Measures

Screening ranges are not construction estimates. Site economics appear only where both implementation cost and annual cost savings have named sources.

No-cost and low-cost measures

MeasureSystemSavings rangeAnnual cost savingsSimple paybackSource
HVAC scheduling and setpoint controls
Align occupied schedules, setback/setup temperatures, and overrides with observed business hours without compromising ventilation or comfort.
Controls6% to 8% of whole-building energy$2,735 to $3,647 per year0.2 to 0.5 years[measure-hvac_schedule_setpoint_controls-savings] [sample-contractor-budget] [sample-savings-calculations]

Capital measures

MeasureSystemSavings rangeAnnual cost savingsSimple paybackSource
Interior LED retrofit
Replace eligible fluorescent or legacy interior fixtures with LED equipment after documenting fixture counts, watts, and hours.
Lighting54% to 54% of lighting energy$2,850 to $3,050 per year2.4 to 3.4 years[measure-interior_led_retrofit-savings] [sample-contractor-budget] [sample-savings-calculations]
High-efficiency commercial washer upgrade
Replace end-of-life washers with qualified high-efficiency commercial units after recording cycles, capacity, water temperatures, and utility rates.
Laundry9% to 9% of washer energy$2,100 to $2,800 per year12.9 to 22.9 years[measure-commercial_washer_upgrade-savings] [sample-contractor-budget] [sample-savings-calculations]

Funding Opportunities

USDA Rural Energy for America Program

Administrator
USDA
Geography
United States; rural small-business and site eligibility must be confirmed
Incentive type
Registry status PAUSED for grants; guaranteed-loan lane reported open; resumption watch active
Audit requirement
Audit required. Energy Efficiency Improvement applications require an Energy Audit/Assessment under RD Instruction 4280-B Appendix A.
Credential requirement
The cited registry record does not establish a credential; confirm current Appendix A requirements with USDA

Last verified: July 11, 2026 [funding-usda-reap]

Credentialed Reviewer

Pending credentialed review

Sample reviewer - fictional
Professional engineer review required
Credential identifier: SAMPLE ONLY - no credential asserted
Jurisdiction: Vermont

Reviewer signature

Draft Assessment Disclaimer

Draft assessment. This report is a screening-level ASHRAE Level 1 work product prepared from owner-provided records and walkthrough evidence. It is not a certified, stamped, or sealed engineering report. A credentialed reviewer must review and sign it when a law, lender, or funding program requires that credential.

Source Register

  1. [sample-property-profile] Synthetic owner intake for Bright Coin Laundry. SAMPLE input ledger: fictional property profile dated July 11, 2026
  2. [sample-utility-ledger] Synthetic 12-month utility ledger for Bright Coin Laundry. SAMPLE input ledger: August 2025 through July 2026
  3. [benchmark-reference] Benchmark reference. U.S. EIA 2018 CBECS Table C4, Service row: 37.3 kBtu/sf median building-level site intensity and $1.05/sf gross energy expenditure intensity. The national Service category includes laundromats and is used here as a broad, non-climate-normalized reference. https://www.eia.gov/consumption/commercial/data/2018/ce/xls/c4.xlsx
  4. [sample-walkthrough] Synthetic walkthrough ledger for Bright Coin Laundry. SAMPLE evidence set: fictional nameplates, schedules, fixture inventory, photos, and owner responses dated July 11, 2026
  5. [measure-hvac_schedule_setpoint_controls-savings] Savings basis for HVAC scheduling and setpoint controls. U.S. DOE BTO/PNNL, Impacts of Commercial Building Controls on Energy Savings and Peak Load Reduction, 2017: scheduling (~6%) and setpoint (~8%).
  6. [sample-contractor-budget] Synthetic contractor budget ranges for the fictional property. SAMPLE input ledger: contractor budget screen dated July 11, 2026
  7. [sample-savings-calculations] Deterministic sample savings calculations. SAMPLE calculation ledger using the synthetic 12-month utility total, synthetic fixture and washer inventories, and each cited public savings basis
  8. [measure-interior_led_retrofit-savings] Savings basis for Interior LED retrofit. U.S. DOE Better Buildings, 2018 Interior Lighting Campaign results: participating projects cut lighting energy by 54% on average.
  9. [measure-commercial_washer_upgrade-savings] Savings basis for High-efficiency commercial washer upgrade. EPA ENERGY STAR, Commercial Clothes Washers product overview: certified models average 9% greater energy efficiency than standard models.
  10. [funding-usda-reap] USDA REAP registry source captured July 11, 2026. https://www.dtnpf.com/agriculture/web/ag/news/business-inputs/article/2026/04/01/usda-halts-reap-grant-applications